Share Icon

MATCOR's MMB™–RM Ribbon Mesh Anode

The MATCOR MMB™-Ribbon Mesh Anode is typically used in concrete applications.

The ribbon mesh anode is field assembled with titanium conductor bar and a resistance welder.  The design life of the anode varies with operating current.  The following chart provides some of the basic information you may require.  If you need additional information please contact us

 

TECHNICAL FEATURES


MMP/Ti Ribbon Mesh
anode 0.5" wide

MATCOR
Model Code

Width

Anode Rating for
110 mA/m2 FHWA limits

Electrical
Resistance of
Ribbon Anode 

MMB-0.5-RM-3.5

0.5"
(12.7mm) 

1.1 mA/ft
(3.5 mA/m) 

0.12 ohms/ft
(0.39 ohms/m) 

MMB-0.5-RM-4.1 0.59"
(12.7mm)
1.25 mA/ft
(4.1 mA/m) 
0.10 ohms/ft
(0.33 ohms/m)
MMB-0.5-RM-7.0 1.0"
(12.7mm)
2.1 mA/ft
(7.0 mA/m) 
0.06 ohms/ft
(0.20 ohms/m)

TECHNICAL RESOURCES

The MATCOR MMB™ RM Ribbon Mesh (PDF Overview)

Click here to download the PDF Overview