BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Matcor, Inc. - ECPv6.18.0//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Matcor, Inc.
X-ORIGINAL-URL:https://www.matcor.com
X-WR-CALDESC:Events for Matcor, Inc.
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20140309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20141102T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20150308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20151101T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20160313T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20161106T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20150512
DTEND;VALUE=DATE:20150515
DTSTAMP:20150416T011956Z
CREATED:20150416T005956Z
LAST-MODIFIED:20150416T011956Z
UID:3676-1431388800-1431647999@www.matcor.com
SUMMARY:NACE UAE Corrosion Conference
DESCRIPTION:MATCOR to present “Applications of Impressed Current Linear Anodes in Cathodic Protection” at NACE UAE Corrosion Conference \nShailesh Javia\nDirector\, MATCOR International\nTime\, Date & Location TBA \nFlexible impressed current linear Anodes that extend the benefits  of linear anodes to the widest range  of cathodic protection applications. Tight spaces\, high traffic areas\, poorly coated pipelines\, New Construction tank bottom\, tank bottom retrofits\, reinforcing steel-in-concrete\, sheet pile walls or inside large diameter pipes – linear anodes for many Cathodic Protection Applications. \nLinear anodes handle current distribution challenges by minimizing current densities and placement in close proximity to the structure. Innovative design utilizing multiple internal connections provides redundancy\, protects against uneven  anode consumption and minimizes  voltage drop. Linear Anode can simply  be laid alongside a new pipeline; cable  plowed next to an existing pipeline\, or  installed utilizing horizontal directional  drilling (HDD) under an existing  structure. Linear Anodes require only a small trench for installation\, ideal for congested areas and minimizing landowner “right of way” issues. \nContact Shailesh Javia to connect during the NACE UAE Corrosion Conference: \n+91 79 26588551 | E-mail
URL:https://www.matcor.com/event/nace-uae-corrosion-conference/
LOCATION:St. Regis Abu Dhabi\, Nation Towers\, P.O. Box 60476\, Corniche\, Abu Dhabi\, United Arab Emirates
END:VEVENT
END:VCALENDAR