Copper Sulfate Reference Electrodes

Copper Sulfate Reference Electrodes

MATCOR copper sulfate (CuSO4) reference electrodes are permanent CP monitoring cells for underground, water tank, and freshwater applications. Available in underground-packaged, under-tank, and freshwater configurations, oversized for longer life and tested to ±10 mV.

Copper Sulfate Reference Electrodes Key Benefits

Extended life from larger copper sulfate reservoir
Reliable performance underground and in freshwater
Suitable for underground and under-tank use
Moisture-retaining backfill for accurate readings

Types of Copper Sulfate Reference Electrodes

Copper sulfate reference electrodes are available in underground and freshwater styles. Since our permanent CuSO4 cells are larger than the norm, they have more copper sulfate than others and, therefore, have a longer life.

We offer three basic types:

Basic Copper Sulfate Reference Electrodes

  • Underground and water tank
  • Dimensions: 2-inch diameter x 10 inches long
  • Chloride ion trap in heat formed recess
  • Lead wire: 25 ft #14 HMWPE stranded copper
  • All tested for + or – 10 millivolts to standard electrode

Underground CuSO4 Reference Electrodes

  • Basic electrode is packaged in prepared backfill to retain moisture contact and electrode stability
  • Size: 10-inch diameter x 24 inches long
  • Weight: 25 pounds
  • Model code: PRC-CU4-UG

Under Tank CuSO4 Reference Electrodes

  • Small profile for under tank applications
  • Size: 3″ dia. x 24″
  • Weight: 3 lbs.
  • Model code: PRC-CU4-UT

Freshwater CuSO4 Reference Electrodes

  • Basic electrode has extended shield over porous plug to avoid contact with structure
  • Model code: PRC-CU4-WT

NOTE: Reference electrodes listed above represent standard sizing. MATCOR CuSO4 Reference Electrodes can also be produced to your size and lead wire type specifications. Please contact MATCOR for additional information.

Why MATCOR Materials?

MATCOR engineers and manufactures proprietary cathodic protection products in the USA, combining proven field performance with the quality systems and supply chain control that critical infrastructure demands.

Made in the USA, Built for the Field

Proprietary products manufactured in-house with millions of documented operating hours and reliable domestic supply chain control.

Engineered To Perform, Not Just Comply

Products designed by our own corrosion engineers to solve real-world problems, not just meet spec.

Proven Quality Systems

ISO 9001:2015 certified manufacturing with structured quality control and built-in continuous improvement processes.

Backed by Global Resources

The specialized expertise of a corrosion engineering company combined with the systems and oversight of a $6B global industrial services organization.

From application review to delivery and field support, getting the right CP and AC mitigation materials is an engineering decision—not just a purchase. Here’s what working with MATCOR looks like.

 Recently Viewed

No data was found

 Related services

An ACCA survey evaluates buried pipeline coating condition by measuring how an applied AC signal attenuates along the line. Sound coating holds the signal; damaged coating bleeds it into the soil. The rate of attenuation qualitatively ranks coating quality by segment and flags the areas with the most significant holidays.
Alternating Current Voltage Gradient (ACVG) surveys pinpoint buried pipeline coating defects and holidays, helping operator teams evaluate pipeline integrity and protect critical underground infrastructure.
Cathodic protection testing must be performed on a regular basis to maintain regulatory compliance and ensure continued corrosion protection of your assets. MATCOR conducts annual CP surveys that go beyond checking a box—our technicians collect the data, and our corrosion engineers interpret it and act on it.
An atmospheric corrosion survey evaluates whether airborne elements — such as sea salt, corrosive chemical plant discharge, or dust — are contributing to a structure’s corrosion. MATCOR technicians inspect the structure, test air and surface deposit samples, and deliver a full report with findings and recommendations.

 Related Resources

Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.

Ready to solve your corrosion challenges with the Most Technically Capable team in the industry?

Contact a Corrosion Expert or a Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.

FLASH RECTIFIER SALE

Need a Rectifier Now? We Have It.

Get a tested MATCOR rectifier without the manufacturing wait. Our in-stock units are ready to ship. Limited quantities available.

Rusty—MATCOR Mascot

Ask Rusty

Your guide to MATCOR services, products, and corrosion protection. Prefer a person? Use the Contact link below.

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.