Feasibility Studies
Page 4

Feasibility Studies

MATCOR's cathodic protection feasibility studies determine whether structures like pipelines, deep wells, or above-ground storage tanks require corrosion protection, combining on-site testing with a review of engineering drawings and corrosion history. Backed by over 5 decades of experience, we deliver a full report covering feasibility, approximate budgetary costs, and recommended CP system types.
Cathodic Protection Feasibility Study

How do you determine if cathodic protection is needed?

Cathodic protection (CP) feasibility studies are performed to determine if there is a requirement for cathodic protection of structural assets such as gas pipelines, deep wells or above ground storage tanks (ASTs). Feasibility studies include:

  • On-site corrosion testing
  • Review of engineering drawings for the structure to be protected
  • Review of the structure’s corrosion history

Once on-site corrosion testing and analysis is complete, and engineering drawings and corrosion history have been reviewed, the best method of cathodic protection for the application must be determined.

MATCOR has over 50 years of experience in cathodic protection and assessing the need for corrosion prevention. Our corrosion experts will come to your facility to:

  • Gather and analyze data for the structure and surrounding environment
  • Provide expert review of your engineering drawings and corrosion history

Next, we will provide a full report that includes:

  • The feasibility of using cathodic protection
  • Approximate budgetary costs
  • A complete review of the types of cathodic protection systems recommended for your application

Feasibility Studies Key Benefits

No data was found

Why MATCOR Services?

MATCOR combines engineering expertise, proprietary products, and specialized installation capabilities to deliver corrosion protection solutions from design through commissioning and beyond.

One Partner, The Right Solution

Engineering, materials, installation, and more from the most techically capable team in the industry.

Leading Installation Capacity

Specialized equipment and dedicated construction crews ready to mobilize.

Engineering-Driven Approach

We don’t simply execute specs—we solve complex corrosion problems. 

50+ YEAR Quality & Safety RECORD

ISO 9001:2015 certified and backed by BrandSafway’s global resources.

Your AC mitigation and CP systems are only as good as the teams that design, install, and manage them. From engineering review through commissioning and annual surveys, here’s how MATCOR gets it right in the field.

 Recently Viewed

matcor durammo deep anode system

Why the Durammo Deep Anode Groundbed System Doesn’t Need Centralizers

Railroad stray current

Stray Current Corrosion: Common Types of Stray Current Interference

Power Plant

Why Cathodic Protection Fails in Power Plants (and How to Fix It)

Tank Cathodic Protection Design App - Screenshot

Tank Cathodic Protection System Design App

No data was found

 Related Products

MATCOR’s elevator cathodic protection system protects the internal surfaces of hydraulic elevator piston casings using impressed current or sacrificial anode methods. Systems include reference electrodes and a rectifier and are available for new installations or as a retrofit.
Galvanic anodes, also known as sacrificial anodes, provide proven, maintenance-free corrosion prevention for steel structures buried in soil or submerged under water. MATCOR manufactures and supplies high-quality aluminum, zinc, and magnesium sacrificial anodes engineered for pipeline, tank, and marine applications.
The MATCOR MITIGATOR® Gradient Control Mat protects workers near cathodic-protection pipelines from lightning, AC fault current, and steady-state AC induction hazards. Supplied on a reel, it installs in concentric rings around appurtenances and connects to the pipe via a decoupler.
MATCOR graphite anodes are impressed current anodes available in 3″ and 4″ diameter sizes, supplied bare with lead wire or packaged in coke backfill. Cable options include HMWPE, Halar, and Kynar/HMWPE insulations in various lengths and gauges.

 Related services

Cathodic Protection Commissioning

CP System Commissioning

cathodic protection well abandonment

CP Well Abandonment

Decoupler Installation

Decoupler Installation

durammo deep anode system installation

Deep Anode Bed Installation

Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.
This field is hidden when viewing the form
This field is hidden when viewing the form

Ready to solve your corrosion challenges with the Most Technically Capable team in the industry?

Contact a Corrosion Expert or a Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.
This field is hidden when viewing the form
This field is hidden when viewing the form
Rusty—MATCOR Mascot

Ask Rusty

Your guide to MATCOR services, products, and corrosion protection. Prefer a person? Use the Contact link below.

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.
This field is hidden when viewing the form
This field is hidden when viewing the form