Regular CP system evaluations confirm that your cathodic protection equipment is functioning correctly and delivering adequate protection across all protected structures. MATCOR performs structured evaluations that go beyond spot-checking—our engineers review rectifier output, test station data, and pipe-to-soil potentials together to assess overall system health.
CP System Evaluation

System evaluations are scheduled proactively as part of ongoing maintenance programs, providing operators with the documentation they need for regulatory compliance and long-term asset management. System evaluation services include:

  • Rectifier output checks and adjustment
  • Pipe-to-soil potential measurements at test stations
  • Bond and isolation fitting verification
  • Assessment of CP criteria compliance
  • Written evaluation report with maintenance recommendations

System Evaluation Key Benefits

No data was found

Why MATCOR Services?

MATCOR combines engineering expertise, proprietary products, and specialized installation capabilities to deliver corrosion protection solutions from design through commissioning and beyond.

One Partner, The Right Solution

Engineering, materials, installation, and more from the most techically capable team in the industry.

Leading Installation Capacity

Specialized equipment and dedicated construction crews ready to mobilize.

Engineering-Driven Approach

We don’t simply execute specs—we solve complex corrosion problems. 

50+ YEAR Quality & Safety RECORD

ISO 9001:2015 certified and backed by BrandSafway’s global resources.

Your AC mitigation and CP systems are only as good as the teams that design, install, and manage them. From engineering review through commissioning and annual surveys, here’s how MATCOR gets it right in the field.

 Recently Viewed

matcor durammo deep anode system

Why the Durammo Deep Anode Groundbed System Doesn’t Need Centralizers

Railroad stray current

Stray Current Corrosion: Common Types of Stray Current Interference

Power Plant

Why Cathodic Protection Fails in Power Plants (and How to Fix It)

Tank Cathodic Protection Design App - Screenshot

Tank Cathodic Protection System Design App

No data was found

 Related Products

Decouplers for AC mitigation systems are available from MATCOR, which distributes Dairyland decoupler products for use in pipeline AC mitigation project designs.
The Durammo® Deep Anode Casing Kit is a factory-assembled PVC termination kit for the top of deep anode boreholes, accommodating vent pipe, cable, and lowering rope connections. Available in 10″ or 12″ diameter and 5, 10, or 20-foot lengths, it requires no field assembly.
The MATCOR PRC-AGCL-ZN-X is a direct drive dual reference electrode combining silver chloride and zinc sensors in compacted reference electrode backfill. A built-in driving cone enables installation in soft soil or sand to depths of 40 feet without drilling equipment.
The MATCOR Driving Cone Anode (DCA) is a complete impressed current system for installing packaged MMO anodes in soft soils without drilling or excavation. Using a pneumatic hammer or drill rig, DCA anodes can be driven to depths of 30 feet or more.

 Related services

Cathodic Protection Budget Estimates

Budget Estimates

cathodic protection rectifier

Cathodic Protection Rectifier Installation & Commissioning

pipeline inspection done by two men

Close Interval Survey (CIS)

Coating Conductance Testing

Coating Conductance Testing

Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.

Ready to solve your corrosion challenges with the Most Technically Capable team in the industry?

Contact a Corrosion Expert or a Request a Quote

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.

FLASH RECTIFIER SALE

Need a Rectifier Now? We Have It.

Get a tested MATCOR rectifier without the manufacturing wait. Our in-stock units are ready to ship. Limited quantities available.

Rusty—MATCOR Mascot

Ask Rusty

Your guide to MATCOR services, products, and corrosion protection. Prefer a person? Use the Contact link below.

Please complete the form and a member of the MATCOR team will contact you within 24 hours.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Request Quote
Consent
I understand my information will be stored securely for the sole purpose of conducting business with MATCOR, Inc. I agree to receive future email communication and understand that I may opt out at any time. View our Privacy Policy.